<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Emniyet Kontrolörleri &#8211; Muhammet Işık</title>
	<atom:link href="https://muisik.com/tr/tag/emniyet-kontrolorleri/feed/" rel="self" type="application/rss+xml" />
	<link>https://muisik.com</link>
	<description>Endüstriyel Çözm Mimarı</description>
	<lastBuildDate>Thu, 19 Mar 2026 21:29:56 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://muisik.com/wp-content/uploads/2026/01/cropped-favicon-32x32.png</url>
	<title>Emniyet Kontrolörleri &#8211; Muhammet Işık</title>
	<link>https://muisik.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Safety-Critical HMI Sistemlerinde Fieldbus Entegrasyonu</title>
		<link>https://muisik.com/tr/safety-critical-hmi-sistemlerinde-fieldbus-entegrasyonu/</link>
		
		<dc:creator><![CDATA[Muhammet Işık]]></dc:creator>
		<pubDate>Thu, 19 Mar 2026 18:39:44 +0000</pubDate>
				<category><![CDATA[Sistem Entegrasyonu]]></category>
		<category><![CDATA[Projeler]]></category>
		<category><![CDATA[Demiryolu Sinyalizasyonu]]></category>
		<category><![CDATA[Emniyet Kontrolörleri]]></category>
		<category><![CDATA[Emniyet Kritik Sistemler]]></category>
		<category><![CDATA[Endüstriyel Haberleşme Protokolleri]]></category>
		<category><![CDATA[Endüstriyel Kontrol Sistemleri]]></category>
		<category><![CDATA[Portfolyo]]></category>
		<guid isPermaLink="false">https://muisik.com/?p=2400</guid>

					<description><![CDATA[ANSYS SCADE Display platformunda tasarlanan HMI ekranlarının, sahadaki HIMA HiMatrix F35 güvenlik PLC'leri ile Modbus TCP/IP üzerinden haberleşmesini sağlayan C99 tabanlı standart bir middleware.]]></description>
										<content:encoded><![CDATA[
<p>ANSYS SCADE Display platformunda tasarlanan HMI ekranlarının, sahadaki&nbsp;<strong>HIMA HiMatrix F35</strong>&nbsp;güvenlik PLC&#8217;leri ile&nbsp;<strong>Modbus TCP/IP</strong>&nbsp;üzerinden haberleşmesini sağlayan C99 tabanlı standart bir middleware.</p>



<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p><strong>Kapsam:</strong>&nbsp;SCADE&#8217;in kapalı döngü yapısı ile kontrol katmanı arasında veri alışverişini sağlamak amacıyla geliştirilmiş, zero-copy prensibiyle çalışan bir entegrasyon uygulaması.</p>
</blockquote>





<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading" id="proje-k%C3%BCnyesi">Proje Künyesi</h2>


<div class="kb-table-container kb-table-container2400_bd1692-fc wp-block-kadence-table"><table class="kb-table kb-table2400_bd1692-fc">
<tr class="kb-table-row kb-table-row2400_ef8ce0-21">
<th class="kb-table-data kb-table-data2400_7b4186-4b">

<p>Parametre</p>

</th>

<th class="kb-table-data kb-table-data2400_ffa06e-24">

<p>Değer</p>

</th>
</tr>

<tr class="kb-table-row kb-table-row2400_d3b948-28">
<td class="kb-table-data kb-table-data2400_1d068a-2a">

<p><strong>Kategori</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_306cc1-27">

<p>Sistem Entegrasyonu</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_38d40b-5a">
<td class="kb-table-data kb-table-data2400_e4cc7b-5e">

<p><strong>Teslimat Tipi</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_ede8cc-9e">

<p>Embedded Middleware</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_7ead4d-e1">
<td class="kb-table-data kb-table-data2400_98a5fa-81">

<p><strong>Durum</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_69f4a3-d2">

<p>Proof of Concept / Akademik Bildiri Yayınlandı</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_b87980-1e">
<td class="kb-table-data kb-table-data2400_b0886b-ff">

<p><strong>Rol</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_2c13b8-67">

<p>Embedded Systems Developer</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_8bbf9c-b9">
<td class="kb-table-data kb-table-data2400_61b7d3-d0">

<p><strong>Ölçek / Kapsam</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_73ed0a-1c">

<p>Lokal Haberleşme (4 Hat Kesimi, 6 Sinyal, 1 Makas)</p>

</td>
</tr>
</table></div>


<h2 class="wp-block-heading" id="mevcut-durum-ve-sorun">Mevcut Durum ve Sorun</h2>



<p><strong>Bağlam:</strong>&nbsp;İTÜ Raylı Sistemler Laboratuvarı&#8217;ndaki anklaşman simülasyon sisteminin endüstriyel standartlara uygun HMI yapısına taşınması.&nbsp;<strong>Kritik Sorunlar:</strong>&nbsp;SCADE Display kapalı sistem mimarisi nedeniyle HIMA PLC&#8217;ler ile Modbus haberleşmesi kurulamaması ve dinamik saha konfigürasyonu eksikliği.</p>


<div class="kb-table-container kb-table-container2400_b247b5-f7 wp-block-kadence-table"><table class="kb-table kb-table2400_b247b5-f7">
<tr class="kb-table-row kb-table-row2400_defc20-d6">
<th class="kb-table-data kb-table-data2400_5ca987-99">

<p>Bileşen</p>

</th>

<th class="kb-table-data kb-table-data2400_79878c-f1">

<p>Durum / Gereksinim</p>

</th>
</tr>

<tr class="kb-table-row kb-table-row2400_cf47b9-b8">
<td class="kb-table-data kb-table-data2400_9b6904-58">

<p><strong>HMI Platformu</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_2c4089-f2">

<p>SCADE Display içerisinde yerleşik (native) Modbus arayüzünün bulunmaması</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_5b8a6c-f9">
<td class="kb-table-data kb-table-data2400_7f7d47-51">

<p><strong>Kontrol Katmanı</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_87592d-de">

<p>HIMA HiMatrix F35 PLC&#8217;ler ile Modbus TCP/IP üzerinden haberleşme zorunluluğu</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_8df41b-1a">
<td class="kb-table-data kb-table-data2400_c71bd7-f5">

<p><strong>Saha Konfigürasyonu</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_e9177c-f7">

<p>Her istasyon için değişen IP/port ve register haritalarının (runtime) yönetimi</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_73ac8d-c1">
<td class="kb-table-data kb-table-data2400_b0a621-68">

<p><strong>Sistem Boyutu</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_275763-4d">

<p>4 hat kesimi, 6 sinyal, 1 makas ve 4 rotadan oluşan lokal anklaşman devresi</p>

</td>
</tr>
</table></div>


<h2 class="wp-block-heading" id="%C3%A7%C3%B6z%C3%BCm-mimarisi-ve-aksiyon">Çözüm Mimarisi ve Aksiyon</h2>



<h3 class="wp-block-heading" id="mimari-yakla%C5%9F%C4%B1m">Mimari Yaklaşım</h3>



<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p><strong><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4a1.png" alt="💡" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Mimari Kısıt Değerlendirmesi:</strong>&nbsp;SCADE platformu&nbsp;<code>DO-178C / EN 50128</code>&nbsp;sertifikasyon bütünlüğünü korumak adına tüm asenkron dış ağ operasyonlarından arındırılmış&nbsp;<strong>&#8220;kapalı bir sistem&#8221;</strong>&nbsp;tasarım felsefesine sahiptir. Bu nedenle laboratuvardaki fiziksel PLC entegrasyonu için doğrudan dışarıdan asenkron çalışan bağımsız bir middleware katmanının geliştirilmesi zorunlu olmuştur.</p>
</blockquote>



<p>SCADE&#8217;in ürettiği kod ile libmodbus arasında bir&nbsp;<strong>C99 middleware wrapper</strong>&nbsp;katmanı tasarlandı:</p>



<figure class="wp-block-kadence-image kb-image2400_b760bb-c6 size-full"><img fetchpriority="high" decoding="async" width="633" height="252" src="https://muisik.com/wp-content/uploads/2026/03/scade-middleware-mimari.png" alt="" class="kb-img wp-image-2411" srcset="https://muisik.com/wp-content/uploads/2026/03/scade-middleware-mimari.png 633w, https://muisik.com/wp-content/uploads/2026/03/scade-middleware-mimari-300x119.png 300w" sizes="(max-width: 633px) 100vw, 633px" /></figure>



<h3 class="wp-block-heading" id="haberle%C5%9Fme-ak%C4%B1%C5%9F%C4%B1">Haberleşme Akışı</h3>



<figure class="wp-block-kadence-image kb-image2400_b2cc55-43 size-full"><img decoding="async" width="691" height="242" src="https://muisik.com/wp-content/uploads/2026/03/scade-middleware-haberlesme.png" alt="" class="kb-img wp-image-2410" srcset="https://muisik.com/wp-content/uploads/2026/03/scade-middleware-haberlesme.png 691w, https://muisik.com/wp-content/uploads/2026/03/scade-middleware-haberlesme-300x105.png 300w" sizes="(max-width: 691px) 100vw, 691px" /></figure>



<h3 class="wp-block-heading" id="uygulanan-metodoloji">Uygulanan Metodoloji</h3>



<ul class="wp-block-list">
<li><strong>Zero-Copy Entegrasyon:</strong>&nbsp;SCADE ana döngüsüne doğrudan hook yaparak kopya maliyetini ortadan kaldırdık.</li>



<li><strong>Dinamik Konfigürasyon:</strong>&nbsp;Saha kurulumunda yeniden derleme gerektirmemek için&nbsp;<strong>3 bölümlü INI dosyası</strong>&nbsp;kullandık.</li>
</ul>



<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p><strong>Güvenlik mekanizması:</strong>&nbsp;Eksik veya bozuk konfigürasyon dosyası algılandığında, sistem varsayılan ayarları (localhost bağlantısı) otomatik oluşturur ve kaydeder.</p>
</blockquote>



<ul class="wp-block-list">
<li><strong>Auto-Reconnection:</strong>&nbsp;Endüstriyel ortamlarda bağlantı kopmaları kaçınılmazdır.</li>



<li><strong>Değişim Algılama (Change Detection):</strong>&nbsp;Ağ trafiğini optimize etmek için&nbsp;<strong>batch read ve selective write</strong>&nbsp;stratejisi uygulandı.</li>
</ul>



<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p><strong>Mimari Karar:</strong>&nbsp;HMI donanımlarında fiziksel olarak eşzamanlı çoklu komut işleme durumu kısıtlı olduğundan, çıkışlar sıralı bir döngüde değerlendirilir. Bu yapısal tercih, gereksiz fieldbus trafiğini (network flooding) engeller.</p>
</blockquote>



<ul class="wp-block-list">
<li><strong>Thread-Safe Logging:</strong>&nbsp;Kritik sistemlerde her olay kaydedilmelidir.</li>
</ul>



<h3 class="wp-block-heading" id="ankla%C5%9Fman-kapsam%C4%B1">Anklaşman Kapsamı</h3>


<div class="kb-table-container kb-table-container2400_c9f611-fa wp-block-kadence-table"><table class="kb-table kb-table2400_c9f611-fa">
<tr class="kb-table-row kb-table-row2400_41ffee-4d">
<th class="kb-table-data kb-table-data2400_9449b3-a4">

<p>Bileşen</p>

</th>

<th class="kb-table-data kb-table-data2400_17fada-d6">

<p>Adet</p>

</th>

<th class="kb-table-data kb-table-data2400_28453f-31">

<p>Detay</p>

</th>
</tr>

<tr class="kb-table-row kb-table-row2400_a1fcf6-8c">
<td class="kb-table-data kb-table-data2400_5ec42f-fe">

<p><strong>Hat Kesimi (TC)</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_baddcd-e7">

<p>4</p>

</td>

<td class="kb-table-data kb-table-data2400_be661f-83">

<p>TC01–TC04</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_bfcf5d-b3">
<td class="kb-table-data kb-table-data2400_d89a63-31">

<p><strong>Sinyal (SN)</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_58a840-33">

<p>6</p>

</td>

<td class="kb-table-data kb-table-data2400_19f592-8c">

<p>Giriş + çıkış sinyalleri</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_b07363-55">
<td class="kb-table-data kb-table-data2400_a8ac09-a8">

<p><strong>Makas (SW)</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_c947d7-2c">

<p>1</p>

</td>

<td class="kb-table-data kb-table-data2400_ad00f5-ac">

<p>Normal / Reverse</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_7f7082-f3">
<td class="kb-table-data kb-table-data2400_e5d66c-fc">

<p><strong>Rota (RT)</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_208f8b-1d">

<p>4</p>

</td>

<td class="kb-table-data kb-table-data2400_32f5c4-05">

<p>RT01–RT04 kombinasyonları</p>

</td>
</tr>
</table></div>


<p><strong>Örnek rota:</strong>&nbsp;RT01: SN01E → TC01 → TC04 → TC02 → SN02E (Makas: Normal)</p>



<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p><strong>Emniyet Kuralı:</strong>&nbsp;Kritik tasarım ilkeleri gereği, sistem tarafından açıkça talep edilmeyen tüm sinyaller varsayılan olarak kısıtlayıcı duruma (kırmızı) geçecek şekilde kurgulanmıştır.</p>
</blockquote>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading" id="sonu%C3%A7lar-ve-operasyonel-kazan%C4%B1mlar">Sonuçlar ve Operasyonel Kazanımlar</h2>



<p><strong>Sayısal Kazanım:</strong>&nbsp;<em>(PoC düzeyinde laboratuvar testlerinde elde edilen potansiyel değerler)</em></p>


<div class="kb-table-container kb-table-container2400_a94396-9a wp-block-kadence-table"><table class="kb-table kb-table2400_a94396-9a">
<tr class="kb-table-row kb-table-row2400_d68259-dd">
<th class="kb-table-data kb-table-data2400_b1974f-1b">

<p>Metrik</p>

</th>

<th class="kb-table-data kb-table-data2400_28cf2d-33">

<p>Değer / Durum</p>

</th>
</tr>

<tr class="kb-table-row kb-table-row2400_8af4b0-d5">
<td class="kb-table-data kb-table-data2400_0c4656-3f">

<p><strong>Döngü Süresi</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_0fd0a9-a3">

<p>~8ms ortalama gecikme</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_30531f-e6">
<td class="kb-table-data kb-table-data2400_104df5-93">

<p><strong>Bağlantı Yönetimi</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_257809-e6">

<p>Hata durumunda otomatik yeniden bağlanma (auto-reconnect)</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_fd4088-65">
<td class="kb-table-data kb-table-data2400_52a376-17">

<p><strong>Konfigürasyon</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_965528-d1">

<p>Parametrik yapı sayesinde derlemeden bağımsız devreye alma</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_84d0f8-9f">
<td class="kb-table-data kb-table-data2400_478410-a8">

<p><strong>Ağ Trafiği</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_021b03-56">

<p>Change detection algoritmaları ile yalnızca değişen register&#8217;ların aktarımı</p>

</td>
</tr>

<tr class="kb-table-row kb-table-row2400_04a115-8a">
<td class="kb-table-data kb-table-data2400_716d2e-67">

<p><strong>Doğrulama</strong></p>

</td>

<td class="kb-table-data kb-table-data2400_456f50-37">

<p>HIMA HiMatrix F35 PLC (SILworX) ve fiziksel test yatağı üzerinde doğrulama</p>

</td>
</tr>
</table></div>


<h2 class="wp-block-heading" id="proje-g%C3%B6rselleri">Proje Görselleri</h2>


<div class="kb-gallery-wrap-id-2400_eb2df1-8b alignnone wp-block-kadence-advancedgallery"><div class="kb-gallery-ul kb-gallery-non-static kb-gallery-type-fluidcarousel kb-gallery-id-2400_eb2df1-8b kb-gallery-caption-style-bottom-hover kb-gallery-filter-none" data-image-filter="none" data-lightbox-caption="true"><div class="kt-blocks-carousel splide kt-carousel-container-dotstyle-dark kt-carousel-arrowstyle-whiteondark kt-carousel-dotstyle-dark kb-slider-group-arrow kb-slider-arrow-position-center" data-slider-anim-speed="400" data-slider-scroll="1" data-slider-arrows="true" data-slider-dots="true" data-slider-hover-pause="false" data-slider-auto="" data-slider-speed="7000" data-slider-type="fluidcarousel" data-slider-center-mode="true" data-slider-gap="10px" data-slider-gap-tablet="10px" data-slider-gap-mobile="10px" data-show-pause-button="false"><div class="splide__track"><ul class="kt-blocks-carousel-init kb-blocks-fluid-carousel splide__list"><li class="kb-slide-item kb-gallery-carousel-item splide__slide"><div class="kadence-blocks-gallery-item"><div class="kadence-blocks-gallery-item-inner"><figure class="kb-gallery-figure kadence-blocks-gallery-item-hide-caption"><div class="kb-gal-image-radius"><div class="kb-gallery-image-contain" ><img decoding="async" src="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-hmi-1024x802.png" width="1024" height="802" alt="" data-full-image="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-hmi.png" data-light-image="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-hmi.png" data-id="2407" class="wp-image-2407 skip-lazy" srcset="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-hmi-1024x802.png 1024w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-hmi-300x235.png 300w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-hmi-768x601.png 768w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-hmi.png 1295w" sizes="(max-width: 1024px) 100vw, 1024px" /></div></div></figure></div></div></li><li class="kb-slide-item kb-gallery-carousel-item splide__slide"><div class="kadence-blocks-gallery-item"><div class="kadence-blocks-gallery-item-inner"><figure class="kb-gallery-figure kadence-blocks-gallery-item-hide-caption"><div class="kb-gal-image-radius"><div class="kb-gallery-image-contain" ><img decoding="async" src="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab3.jpg" width="777" height="518" alt="Model train layout in spacious room" data-full-image="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab3.jpg" data-light-image="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab3.jpg" data-id="2406" class="wp-image-2406 skip-lazy" srcset="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab3.jpg 777w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab3-300x200.jpg 300w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab3-768x512.jpg 768w" sizes="(max-width: 777px) 100vw, 777px" /></div></div></figure></div></div></li><li class="kb-slide-item kb-gallery-carousel-item splide__slide"><div class="kadence-blocks-gallery-item"><div class="kadence-blocks-gallery-item-inner"><figure class="kb-gallery-figure kadence-blocks-gallery-item-hide-caption"><div class="kb-gal-image-radius"><div class="kb-gallery-image-contain" ><img decoding="async" src="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab1.jpg" width="777" height="518" alt="" data-full-image="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab1.jpg" data-light-image="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab1.jpg" data-id="2408" class="wp-image-2408 skip-lazy" srcset="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab1.jpg 777w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab1-300x200.jpg 300w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab1-768x512.jpg 768w" sizes="(max-width: 777px) 100vw, 777px" /></div></div></figure></div></div></li><li class="kb-slide-item kb-gallery-carousel-item splide__slide"><div class="kadence-blocks-gallery-item"><div class="kadence-blocks-gallery-item-inner"><figure class="kb-gallery-figure kadence-blocks-gallery-item-hide-caption"><div class="kb-gal-image-radius"><div class="kb-gallery-image-contain" ><img decoding="async" src="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab2.jpg" width="777" height="518" alt="" data-full-image="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab2.jpg" data-light-image="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab2.jpg" data-id="2409" class="wp-image-2409 skip-lazy" srcset="https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab2.jpg 777w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab2-300x200.jpg 300w, https://muisik.com/wp-content/uploads/2026/03/scade-modbus-lab2-768x512.jpg 768w" sizes="(max-width: 777px) 100vw, 777px" /></div></div></figure></div></div></li></ul></div></div></div></div>


<h2 class="wp-block-heading" id="i%CC%87lgili-ba%C4%9Flant%C4%B1lar">İlgili Bağlantılar</h2>



<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f4c2.png" alt="📂" class="wp-smiley" style="height: 1em; max-height: 1em;" />&nbsp;<strong>Kaynak Kod:</strong>&nbsp;<a href="https://github.com/isikmuhamm/ansys-scade-modbus-integration-middleware" rel="nofollow noopener" target="_blank">Github/ansys-scade-modbus-integration-middleware</a>&nbsp;<br><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/1f517.png" alt="🔗" class="wp-smiley" style="height: 1em; max-height: 1em;" />&nbsp;<strong>TOK 2025 Bildiriyi İndir:</strong>&nbsp;<a href="https://muisik.com/wp-content/uploads/2026/03/demiryolu_scade_modbus_makale.pdf">SCADE Modbus Bildiri (PDF)</a></p>
</blockquote>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p><strong>Yazarlar:</strong>&nbsp;Dora Demir¹, İbrahim Can Kolotoğlu², Muhammet Işık², Serhat Boynukalın³, Mehmet Turan Söylemez²<br>¹ İTÜ Elektronik ve Haberleşme Müh. | ² İTÜ Kontrol ve Otomasyon Müh. | ³ İTÜ Lisansüstü Eğitim Enstitüsü</p>



<p><em>Bu çalışma, İTÜ EEF Raylı Sistemler Laboratuvarı&#8217;nda gerçekleştirilmiş ve&nbsp;<strong>Türkiye Otomatik Kontrol 2025 (TOK 2025)</strong>&nbsp;konferansında yayınlanmıştır.</em></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
